Quantcast
Viewing all 4541 articles
Browse latest View live

Re: Loss of relationship between differential pairs

Hi all,

The design which I have the problem says that HSR is not available.

 

But when I start a new design differential lines can be be routed. In those I can not find Setup > Licensed Modules > High Speed (HSR).


Linking in vesys 2.0

Hi everyone!


I'm new to the vesys software, and I'd like to know if it is possible to link files (PDF, JPG  etc.) in the wiring diagram, or harness? I'm thinking of a simple link, beside the connector for example in the harness design, and is you click on the link the given file or picture is displayed (showing related information related to the connector or wire). I think this would be a great feature, I hope its possible. I will have some other questions too later, there are some things I can't find in the infohub (Help menu).

 

Best regard from Hungary!

Re: Suddenly unable to have multiple software keys / dongles inserted concurrently

Isolation information

Hi everyone!

 

In the harness design if I make isolation to bundles, I have absolutely no information about them. The Infohub says isolation tables should exist, and customizable in the style sets menu. Well in the style sets menu tree I navigate to isolation Layer-> and the table tab does not exist. So I don't have information about the isolation at all (I'd like to see length, part number etc. data). Where could I get visible information about the isolation?

 

Looking forward for your answer!

Altium Designer to Mentor graphics expedition VX.1 PCB design

Hello,

 

I tried following recommendation how to translate pcb design created by using Altium Designer into Expedition VX.1:

How to translate a Altium Designer Project to Expedition PCB?

 

Now, I have problem with translating from PADS to Expedition because I couldn't find PADS to Expedition translator that is suitable for Expedition vx.1.

 

I also read following articles:

 

https://supportnet.mentor.com/portal?do=reference.technote&id=MG44116

https://supportnet.mentor.com/portal?do=reference.technote&id=MG527008

 

Articles give alot of information how to make translation from PADS to old Expedition versions but there is no explanation how to translate it into Expedition VX.1. Also, there is no download link to standalone PADS translator that is suitable for expedition vx.1.

 

Please, can anyone give me an advice how to properly convert PCB design from Altium to Expedition VX.1? Where I can find appropriate translator?

BER

Hai

      I am having ibis model of a ethernet phy and a copper sfp module placed after a distance of 2 inch i need to perfom biterror rate and bathtub simulation for studying the channel is there any link or white paper or videos or steps related to setting is present in mentor support

 

regards

agxin.j

fast eye analysis

hai

     what is the difference between fast eye analysis and eye diagram analysis

regards

agxin.j

Re: Isolation information

Hi Laszlo,

 

In your Style Set, expand Design>Decorations and select Tables.  Then select the green + button at the top to see the Tables available for selection.

After you've added the table in VeSys Harness, you may have to select Actions>Update>Border to have it appear in your design.

 

Image may be NSFW.
Clik here to view.
add table.jpg

 

Hope this helps!

 

Lisa


Re: How to use paste from layout clipboard in VX.1

In Xpedition VX.1, Copy Circuits is native within the Selection Mode.

 

Select your Circuit, and Control+C

Go to your other design and Control + V

 

It is as simple as Copy and Paste in a MS Word Document.

 

Thanks,

Vern Wnek, C.I.D.

Technical Marketing, Xpedition

8247-3230 or 1-949-790-3230 Office

714-264-2417 Cell

Vern_Wnek@Mentor.com<mailto:Vern_Wnek@Mentor.com>

 

<http://www.mentor.com/pcb/xpedition/>Xpedition® VX - next generation pcb design is here – click the X to learn more.

DC2DX Library & Schematic Translator Issues

HI,

 

I am trying to translate our library from DC to DX in 7.9.5 and I am having an issue with some of the parts not translating correctly. I am also try to translate a schematic over to see what issues I would have, and it seems that I do see errors in the log which point back to what I am seeing with the library. As seen below, no pin names in part.

 

Image may be NSFW.
Clik here to view.
DX_CON_1.jpg

If I go to place one of the parts with the issue above from the translated library, I get this error.....

Image may be NSFW.
Clik here to view.
DX_CON_2.jpg

The log file from the library translation is clean and has no warnings or errors. The log from the schematic has an error and a few warnings.....

Release: EE7.9.5

GBS Install Id: 30163

 

Translation start: 5/14/2015 1:51:28 PM

This design contains via span definitions that may be affected

by your layer mapping changes.  Please review the via tab

and update any via spans that require changes.  The via

assignments found in the Net Classes and Clearances Dialog

also need to be checked and modified, if necessary.

File type: (0,0)

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Unable to load bus contents file: C:\Projects\DX_Designs\VHM080\conts.asc

Invalid via inductance value.  Inductance values must

be non-negative and less than or equal to 1000nHUsing inches as base units

[D] Wall clock time: Read() = 00:30

[D] Wall clock time: ConvertIntoInnerDB() = 00:00

Output path: C:\Projects\DX_Designs\VHM080

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Found shorted net. DxDesigner does not support net loops: Deleted segment causing loop from (46228000, 22352000) to (48514000, 22352000) of Net '1P8V_OSC' on ''

[D] Wall clock time: ConvertFromInnerDB() = 00:01

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'CD/DATA3' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'CMD' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'VDD' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'CLK' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'DATA0' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'DATA1' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'DET' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'POL' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND2' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND1' was not found on imported symbol 'Micro_SD_CARD_SLOT_CON.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TRSTn' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TDIS' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'KEY' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND1' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND2' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND3' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'EMU1' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND4' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'EMU3' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'GND5' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TDI' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TVD' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TDO' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TCLKRTN' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'TCLK' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'EMU0' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'SRST' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'EMU2' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'EMU4' was not found on imported symbol 'CON_20PIN_CTI_INTERFACE.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '2' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '3' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '4' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '5' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '6' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '7' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '8' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '11' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '12' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '13' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin '14' was not found on imported symbol 'RJ45_W_LED.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA2+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA2/4_GND' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA4-' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA4+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_DDC_CLK' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_DDC_DATA' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_ANALOG_VERT_SYNC' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA1-' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA1+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA1/3_GND' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA3-' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA3+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_+5V_POWER' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_GND' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_HOT_PLUG_DETECT' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA0-' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA0+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA0/5_GND' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA5-' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_DATA5+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_CLK_GND' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_CLK+' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_TMDS_CLK-' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_C1_ANALOG_RED' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_C2_ANALOG_GREEN' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_C3_ANALOG_BLUE' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_C4_ANALOG_HORZ_SYNC' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_C5_ANALOG_GND0' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'A_C5_ANALOG_GND1' was not found on imported symbol 'DSUB-DVI-I-A.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA2+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA2/4_GND' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA4-' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA4+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_DDC_CLK' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_DDC_DATA' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_ANALOG_VERT_SYNC' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA1-' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA1+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA1/3_GND' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA3-' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA3+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_+5V_POWER' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_GND' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_HOT_PLUG_DETECT' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA0-' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA0+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA0/5_GND' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA5-' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_DATA5+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_CLK_GND' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_CLK+' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_TMDS_CLK-' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_C1_ANALOG_RED' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_C2_ANALOG_GREEN' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_C3_ANALOG_BLUE' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_C4_ANALOG_HORZ_SYNC' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_C5_ANALOG_GND0' was not found on imported symbol 'DSUB-DVI-I-B.1'.

A Same Net Type other than Pad Edge (PE) is not

compatible with the Distance of (Net Class).  Please

enter a valid Distance or change the Type to PE.Pin 'B_C5_ANALOG_GND1' was not found on imported symbol 'DSUB-DVI-I-B.1'.

[D] Wall clock time: yggdb2vd() = 00:18

[D] Wall clock time: Write() = 00:49

[O] Created 339 symbol(s) and 15 schematic sheet(s)

0 error(s) and 101 warning(s) found

Finished on 5/14/2015 at 1:52:49 PM.

 

Out of a 15 page schematic, I was only able to have it translate 7 pages correctly. So I am assuming that once I fix the library issue it will import the schematic correctly? Now my next question is, what is causing the issue, is the way I have the pin text formatted? Dose DX Designer only likes to see pin text the same as the pin number?

Re: identify every instance in netlist from Layout

What tools and versions are you using?

Image may be NSFW.
Clik here to view.

Re: Checklist updation of ERF in Valor

hi,sabitha:

I'm afraid i cann't catch your meaning very well, perhaps you may describe it more detail with it's better with some figure to tell the issue

Especially the dialogue"when running the file with ERF without checklist it works fine", does it mean you ERF manager change will not make any work to the graphic station?

 

Image may be NSFW.
Clik here to view.

Re: identify every instance in netlist from Layout

Hi Samantha

 

I have converted netlist files into schematic in Cadence Virtuoso version IC6.1.5-64b. Please let me know through which tools and version it could be done and how. I will try to get that.

 

Regards

Varun

Re: Isolation information

Hi Lisa!

 

Thank you for the answer, it was really helpful. The "add" button was the one I couldn't notice.

Image may be NSFW.
Clik here to view.

RegisterErrorExpression 오류 문의 드립니다.

HyperLink를 사용하기 Message Window 구문에 Call outTab.RegisterErrorExpression(sRCCPattern, ScriptEngine, "vFunc", "fFunc") 구문을 추가 하였습니다.

 

이때 vbs로 실행 할 때는 정상 동작 하지만, efm에서 실행 할 때는 아래와 같은 에러가 발생 합니다.

 

형식이 일치하지 않습니다. 'outTab.RegisterErrorExpression

 

 

efm에서의 Hyperlink는 어떻게 해야 하는지요?


How to assign all unassigned pins to signals in IO Designer?

Hi all,

 

In IO Designer after importing the UCF file, only one pin is assigned to signal from power and ground group.

Remaining pins are in unassigned pins list.

 

What is the easy method  to assign all unassigned pins to signals?

 

Thanks & Regards,

Murali Bala

how to create custom off page symbol in pads logic ??

i need to create custom off page connector symbol in pads logic and let me know what is mean by logic icon while creating library ??

Sub-component problem

Hi!

 

I've made a sub-component for a connector. The component (which I use as a sub-component in this case) has a symbol attached to it (and the symbol has the same name as the component of course). When I sync with the harness design the connector is visible, with two tables, the connectors table, and the sub components table, but the symbol of the sub component is not. What do I have to do, to make it appear automatically after synchronization (or after applying style)?

 

Thank you!
Best regards from Hungary!

 

 

Image may be NSFW.
Clik here to view.
Rj45.PNG

Re: how to create custom off page symbol in pads logic ??

Off page connectors are defined in the $OSR_SYMS part type found in the Common library unless you've moved it to your own library. 

 

'Logic icon' refers to any PADS Logic symbol in the library that isn't a 'Line' such as borders, notes, logos, etc.

 

Edit $OSR_SYMS and it should make sense from there.

issue in Library part creation in pads logic ??

Hi everyone,

i created CAP part type which contain CAP_0402 and  Alternative part  is CAP_0603.For CAP_0402 symbol i assigned 0402_1 and For CAP_0603 symbol i assigned 0603 decal.

while importing netlist i got error in my design.i assigned pin mapping also even i could not get any thing.is not possible assign the decal for alternate part ??

 

PCB Net List Errors Report - Training1.sch - Mon May 18 18:54:46 2015

----------------------------------------------------------------------

Design to Library Part Consistency Check

----------------------------------------

Part Type CAP has the following gate pins that do not match to the Library part:

(1 0) (2 0).

Non matching Part Type CAP is used by the following parts: C1 C2.

 

Single/Zero Pin Net Warnings

----------------------------

No single or zero pin nets.

 

 

Schematic Connectivity Errors

-----------------------------

No connectivity errors or warnings.

 

1,i need to assign decal for alternate symbol also  is not possible ?? please check image file

what is the meaning for (1 0) (2 0) if it is pin mapping means i assigned pin mapping 1 for 1 and 2 for 2.

 

Image may be NSFW.
Clik here to view.
Capture.JPG

Viewing all 4541 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>