Re: Uncapped via under Component
Sabitha - I will move this post to thic community: https://communities.mentor.com/community/pcb/xpedition/lean_npi.You might want to bookmark it for your convenience. Thanks for using the Mentor...
View ArticleHow to list aggressors in batch crosstalk sim?
I see the aggressor listed in the quick analysis report file, but not in the detailed analysis spreadsheet. How can I do a detailed analysis and get the agressors listed, so that I can track them down...
View ArticleUpdating xDx Databook
Hi all,How can I update xDx databook with latest component information? Is there a some sort of script so that I can run to extract component data from suppliers like Digikey,Mouser ..etc. ? thank you
View ArticleRe: Drill to drill error in stacked blind and buried via in Pads layout 9.5 ???
Hi,it is not working out.still i am getting same error only.is there any option is there.
View ArticleWhat exactly does the demonstration mode in PADS Layout limit? (PADS 9.5)
Hi, Sometimes I'm unlucky and none of the floating licenses are available while I need to open PADS Layout. The software tells me that it will start in demonstration mode instead. What exactly does...
View ArticleCopy Values from CES Class To Class Rules in VX
Hi all, in the Past (7.9.4) it was possible to copy all Values included NetClassNames from CES Class-To-Class Clearances with CTRL-C. But in VX 1.1 it seems to not work anymore ?I need this to check in...
View ArticleRe: Display customer part number Capital Harness XC
Hello,The Customer Part Number is an attribute, so you can add it to your style set under the decorations for an object. For example, for a connector it would look like this... Is that what you were...
View ArticleRe: Drill to drill error in stacked blind and buried via in Pads layout 9.5 ???
See this post Yahoo! Groups from April. A lot of the more experienced users are still on that forum.
View ArticleIntegrator-to-XC Sync Issue
Good morning, I’m running into an issue when I sync wire information froman Integrator plane to a harness in XC where some wires “lose” one connectionpoint. So then, after running design rule checks I...
View ArticleHow to convert Eagle files to DxDesigner?
Hello all, I am trying to convert some Eagle files( .brd and .sch ) to DxDesigner? I want to modify these files in Mentor Graphics. Is there a method to do this or is it even possible? I was looking...
View ArticleRe: How to convert Eagle files to DxDesigner?
Hi Marissa, I've moved your question to the PADS > Schematic Design sub-community where it should receive a quicker answer. Good luck to you!
View ArticleRe: How to convert Eagle files to DxDesigner?
With the latest version of PADS (VX.1) xDX designer has an Eagle schematic importer. It's as easy as file import Eagle, run the translator once to generate the properties to convert and then run the...
View ArticleLooking for a script to resequence reference designators on a Logic schematic?
Check out this script posted by David Ricketts several months ago in the PADS > Schematic design community. Thanks Dave!
View ArticleRe: Importing a .sch Schematic
Using the latest release on PADS VX.1, this file can be imported into xDX Designer Schematic for PADS. Check out File Import Eagle
View ArticleExamples or Tutorials of DxDesigner or Expedition PCB?
Hello, I am trying to learn Mentor Graphics DxDesigner to make schematics and layouts but I can't seem to find any good tutorials online. Are there any examples or tutorials that the community...
View ArticleRe: How to convert Eagle files to DxDesigner?
Hi Gary, Thanks for the response, before I ask more in detail, does DxDesigner fall under PADS? Right now I just have installed Mentor Graphics Dx/Exp EE7.9.3. I don't see any other relation to PADS....
View ArticleRe: How to convert Eagle files to DxDesigner?
My mistake Marissa! Because you were talking about Eagle, I assumed you were interested in PADS. I will move your post to the Xpedition > Design Creation community. You do not need to use PADS.
View ArticleRe: Importing a .sch Schematic
Thanks for the info. I don't have VX.1, but I think someone I know may. I will have to ask him. Thanks again.
View ArticleRe: Integrator-to-XC Sync Issue
Hi John,Do you have any 'refined' connectors in the design? For example, any inline Signal Maps where you have mapped two exclusive wires to the same cavity? I have recently seen a similar issue where...
View ArticleRe: Importing a .sch Schematic
Hi, I have the VX.1 and seems that I can not find how to import schematics from Altium. Can you please advise how to do it, may be my license not covering it ?In my former job I have done a lot of...
View Article