Re: Will Flexnet v11.13.1.2 work on a SPARC server?
Steve, We currently support Solaris 10. Support for SPARC Solaris will be discontinued, likely in the next release. Guy
View ArticleRe: Getting error message Cannot create ActiveX component when calling...
you need to start the IDE using the mglaunch.exe you can create an environment variable for itC:\MentorGraphics\<version>\SDD_HOME\common\win64\bin\mglaunch.exe and then create a batch file that...
View ArticleRe: Getting error message Cannot create ActiveX component when calling...
Hi Andrew, That was the problem. I had some utilities built with EE7.9.5 that didn'trequire this. This is my first build with a VX release. Will need to lookinto what mglaunch actually does. Thank you...
View ArticleRe: Getting error message Cannot create ActiveX component when calling...
All credit goes to Patrick Cashman on here. I was banging my head on this one for way longer than I should have been and he helped me out big time. Just paying it forward at this point.
View ArticleRe: Getting error message Cannot create ActiveX component when calling...
Big Thank you to Patrick Cashman too!. Looked up mglaunch.exe and it isrelated to the changes between EE7.9.5 and the VX releases becauseenvironment variables are no longer defined. Thank you so much!...
View ArticleRe: Getting error message Cannot create ActiveX component when calling...
You can use the following in a vbs script file to get the mglaunch path real time without regard to changes in system settings or installed releases: Optionexplicit run sub run() Dim objShell,...
View ArticleRe: Getting error message Cannot create ActiveX component when calling...
I will give this a try. Thank you so much for your help! Best Regards, Kathy J Brady Principal Software Design Engineer Engineering Solutions Global Business Services Raytheon Company +1...
View ArticleRe: Is there a edit mode to Auto-Route?
Hello Enio I believe you are referring to when you add a Cross-Referenced Conductor and "auto-routing" function in Capital Logic is on.In that case the length of the conductor may appear short compared...
View ArticleRe: x2ml API get wire end components
Well, I found the solution:wire.getStart().getId() will return a String.This String is looking like the following:CONNECTORXXX-22CONNECTOR of course is the object, XXX is the Name of the Object and 22...
View ArticleRe: CHANGE MEG TO M IN DXDATABOOK
Thanks very much Stoane. This solve the problem. This is useful for frequencies values as you mentioned above. We had the same display problem for this field. Thanks again
View ArticleComponent
Hi All,I'm a newbie with automation.I wrote a script that looks up for a certain refdes and manipulate the nets of this refdes. The specific refdes I'm looking for consist of several symbols.I thought...
View ArticleRe: Is it possible to export a Design Capture schematic to VisECAD?
Hi, In Design Capture there is no option to create a .CCE file.Best way is to convert it do DxDesigner. Wim.
View Articlecustom twist report
I am trying to create a custom report for twist information. We generally use a calculation of 7 twist per 305mm of wire. i would like a report to generate how many twist we will need to set our...
View ArticleBundle Length dimension(text) appears on longer bundles
Hi,All of my harness drawings made in a way that most of bundles are laid either horizontally or vertically, so that the bundle length text appear at 0 or 90 degree. No text should appear inclined.By...
View ArticleInstallation Support Training of EE795 or Expedition VX?
What training - either online / computer based or classroom provided - for System Administrators in creating collaborative work environment and basic day-to-day administrative tasks? Not for actual...
View ArticleHow to set up centralized server with multi user access - VESYS Design?
We are using Vesys Design to develop Electrical SchematicsWe have two individual user licenses now in our individual computers. We are moving into a central file location, from where multiple users...
View ArticleRe: Bundle Length dimension(text) appears on longer bundles
Hi VijayanYou are correct that by default the test appears along the bundle orientation. Therefore, please change the default.Edit - Styleset - below you see the Bundle - Atribute - Length. I have...
View ArticleRe: Component
The component, as you are using it (scomp & comp) consists only of a single symbol. There is not an object like what you describe, an scomp which includes several symbols. But let us digress for a...
View ArticleCenter Dot Drill Hole Open in Bottom Layer
As per the manual drill process required to open in pad center for drill in pad center manually.The drill hole open required in single side board bottom layer.Is it possible in PADS Layout or any other...
View ArticleRe: toggle items in display control
If you just want to toggle between active layers with the numeric keys there is already a button to activate this in the Smart Utilities toolbar.Hint: Search for Smart Utilities User Guide on SupportNet
View Article