Quantcast
Channel: Mentor Graphics Communities: Message List
Browsing all 4541 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

Symbol Editor - difficulty selecting overlapping properties

I'm editing/customizing a title block symbol. Some of the properties, such as @PRINTORDER and @SHEETTOTAL, are very close to each other horizontally. In this case, I want to see 'm of n' on the title...

View Article


ADMS error during spice simulation

Hi,I am doing a Serdes spice simulation using Hyperlynx 9.3. I am trying to incorporate a driver spice model as well as a connector touchstone model into the schematic. But, when both these models are...

View Article


Re: Is there a decryption tool for EDX similar to the decryption for HKP's...

EDX is an open standard. Content of EDX can be read/created using any code (based on spec) or with use of EDX-SA Utilities (www.edx-sa.com).As far as Mentor provided content in EDX, there are portions...

View Article

Re: Can we use PartQuest Symbols in pads Logic?

Hi Gray,Is mentor team having any plan to upgrade for the feature of using part-quest symbols in to Pads Logic.

View Article

Image may be NSFW.
Clik here to view.

Re: Can we use Pads 9.5 version even after i updated to pads Standard.

Thank you for the reply robert. I can explain you my need in short and understandable way.I was using 9.5, now i feel like upgrading to pads standard, so here the pads standard license file will be...

View Article


3D via modelling in hyperlynx v9.2

I am using hyperlynx v9.2 for 3D EM simulation, i have exported 3D area of differential via from board sim and assigned the ports, while simulating in MGRID it asks for meshing frequency i gave it as...

View Article

Re: 3D via modelling in hyperlynx v9.2

hi, regarding the result of course I can't say a lot without seeing it. probably somewhere inside of the geometry a connection is not as it should be. But you are right, the solver doesn't solve all...

View Article

Re: 3D via modelling in hyperlynx v9.2

Thanks for the reply.                                              I have used hyperlynx v9.3 nimbic it gave proper result, same via I am simulating in v9.2.I have exported in 3d then there is port...

View Article


Via modeling in hyper lynx IE3D solver.

Hi,I am simulating differential via having cases of back-drilling and without back-drill in order to observe impedance discontinuity. I selected the required 3D area and exported in 3D solver and...

View Article


Re: Via modeling in hyper lynx IE3D solver.

Regarding port assignment there is no difference between backdrilled and not backdrilled. Does the via barrel length really reflect your intention to look at backdrilled and not backdrilled scenario?...

View Article

Re: 3D via modelling in hyperlynx v9.2

In HL3D I have seen very small opens between the polygon which you can look for with the check connection command. In 9.3 based on the HL Advanced Solver technology we don't see this effect. That's why...

View Article

No backups are made?

HiAnyone seen that in some cases PADS does not generate backups - even if the design has changed several times during the day?One of my colleagues has this problem. Sometimes the design is not backed...

View Article

Re: I've installed the license properly however Flowtherm XT just doesn't...

Hi Andrew,Before re-loading the OS, there are a couple more things that you could check:Do you get any error message from FloTHERM XT?Is anything reported in the debug.log file (identified in the...

View Article


Re: Reusable blocks editor grayed out in CL

Both of these features are for the Xpedition flow currently.

View Article

library terminal overlap in symbol during symbol creation

Does anybody know how to prevent a terminal been accidentally overlap with another terminal during library creation? Is there any script to verify library. The current Check part is not able to capture...

View Article


ECO Errors from PADS Logic to PADS Layout

Hello All , We are facing ECO errors in generating correct data for placement files . Sometimes even though the component is placed on the top and placement files is generated component gets swapped in...

View Article

looking for xDX - Project Close / Closing Event

Hello,I am looking for a Event which gets fired when I am closing the complete Project.I found Events whenClosing a Schematic Sheet / Schematic PageClosing / Shutting down xDX Designer has someone here...

View Article


Image may be NSFW.
Clik here to view.

PASS THE REFDES VALUE FROM DXDATABOOK

Hi, is it possbile to pass the REFDES value to a component in the schematic from the databook? I created different symbol for my RESISTORS table (resistor.1, jmp_resistor.1, etc,..) leaving the REFDES...

View Article

Re: Changing symbol in xDx Databook

Thank you Robert. I am using a Central Library.I was able to edit it in the access database so that all the TANT Capacitors are calling out the symbol with polarity.Thank you for your support. 

View Article

Re: ECO Errors from PADS Logic to PADS Layout

First, I've never used the 'ECO Names' tab in my many years of using Logic; I always use the default with no issues.   Second, placement data doesn't transfer from Logic to Layout during the ECO...

View Article
Browsing all 4541 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>