Re: How to verify sub-Contractor Land Patterns
Hello,Thank you for the input. Unfortunately we need to check a few designs the sub just did because in thePast some of the Land Patterns have been wrong. I am going to be using DXD and PADS, ALL...
View ArticleRe: Using VB script to export IDF and DXF formats from Expedition PCB
Matthias, thanks. that was the Trick. I coded, and coded, and ...Anyway, thanks for the input, now it is working fine.
View ArticleRe: can`t close DxDesigner /viewdraw at the end of script !
Thanks for your help PatrickI still can`t close the dxdesigner throw script. But I think it is because I do not have a Automation Pro license.how I get it, it is just possible to access the script...
View ArticleRe: More 7.9.x to VX translations
Finally getting another chance to poke at this some more. Adding a reference to VisualBasic and usingInteraction.CreateObjectappears to be heading in the right direction. I can now create new instances...
View ArticleRe: More 7.9.x to VX translations
I actually found a good test. I just downloaded this from mentorBulk Modification of Library Cells using Visual Basic and it too fails to open the library and crashes with "Could no create ActiveX...
View ArticleRe: More 7.9.x to VX translations
running all of these commands inside or outside of the "MGC PCB Command Window VX.1.1" makes no difference for me.Are you using mglaunch to start your IDE (to run the application in debug mode from...
View ArticleRe: More 7.9.x to VX translations
I've just been compiling the exes and then running those through the "MGC PCB Command Window VX.1.1" which points to ".\MentorGraphics\EEVX.1.1\SDD_HOME\common\win64\bin\mgcmd.exe"
View ArticleRe: More 7.9.x to VX translations
I found the mglaunch.exe and tried using that mglaunch.exe "path\to\my\script.exe" Same activeX error.
View ArticleHow to change a license server PC
We just bought a combo site-float license for Tanner Tools and Calibre. The new license is tied to the MAC address of my desktop PC that is still running WIndowsXP. It seemed not letting me to install...
View ArticleRe: change of community "credentials" (username, reference email ...)
I also need to change my profile Email address. We were acquired a while back, and now we've be moved over to the acquiring company's email domain. I've searched, but was unable to find instructions on...
View ArticleRe: Linker file missing sections
David, it turns out you were sent the wrong version of ReadyStart. The version that matches with your BSP will be provided to you shortly.
View ArticleRe: Linker file missing sections
Is there a BSP that matches the ready start that version I have? David TypeMotorsportsdave@typemotorsports.com
View ArticleProblems with license server
Hi,we got several licenses and tried to setup a license server with the "Mentor Graphics Installation" and the "LMTOOLS" Software. When we checked the license server status we get the following error...
View ArticleRe: Flexnet TIMEOUT option support in PADS Logic.
smercurio, The FlexNet TIMEOUT option is not supported by PADS. Guy
View ArticleRe: How to change a license server PC
Rongching, Please open a Service Request and select Other Request Type > Software Transfer. You'll need to supply the Ethernet address of a PC running Windows 7 or newer....
View ArticleRe: Flexnet TIMEOUT option support in PADS Logic.
Thanks for the response. That's unfortunate, as we were hoping to use that to deal with the issue of PADS Logic often not releasing a checkout of the viewdraw040 license when exiting the application....
View ArticleRe: Flexnet TIMEOUT option support in PADS Logic.
You can try setting TIMEOUTALL 900 in your options file. This may alleviate the problem of licenses not getting checked back in after the application is closed. What is not supported in PADS is an idle...
View ArticleRe: Flexnet TIMEOUT option support in PADS Logic.
I could try that. When I had first read the documentation on the TIMEOUT and TIMEOUTALL options, it said for TIMEOUTALL "Same as TIMEOUT, but applies to all features.", so I didn't expect it to work...
View ArticleRe: Flexnet TIMEOUT option support in PADS Logic.
In short, if PADS is not running, it's no longer communicating with the license server. The license server will check TIMEOUT or TIMEOUTALL to determine when it should check in licenses from clients...
View ArticleRe: Flexnet TIMEOUT option support in PADS Logic.
Thanks for the clarification, Guy. Given this info, it seems worth trying. I'll give it a shot this weekend, as the PADS licenses are in heavy use right now.-Saverio
View Article