Display control Warning 002
HiI just upgraded the design from EE7.9.5 to VX1.1And every time I switch the view from 2D to 3D or opposite, I get two annoying messages: Display Control Warning 002Wronte Template file...
View ArticleRe: 3D PCB viewer
I have downloaded the viewer and unable to load my gerbers. I am using VX.1.1 (update 7) and exported gerbers but they do not import. Does the tool require 274D gerbers or 274x ? Also, can it import...
View ArticleSchematics Text Size And Component Text Size Need To Be Same
Hi All, How To Change The All The Font Size And Style In Single Formatted . At Same Time. Very Good Day,Pavan Kumar
View ArticleRe: AATK_1719 released
Hi All, I am Relatively New To Expedition Kindly Help Me How Use The ATTK Files In My PC.Good Day, Pavan Kumar (PRK)
View ArticleRe: 4K Display Resolution
Hi not sure if you have this in Pads Layout. Here you can say use Large Icons. Go to View--> Toolbars Customice-->OptionTab, very hidden. This looks crap on my screen but maybe good for the 4k...
View ArticleRe: PADS VX.1.1 Error **INPUT WARNINGS FOUND**
HiWhat happens if you run the 'Update from library' function in PADS Logic?1) Open 'Tools > Update from Library'.2) Select 'Generate comparison report'.3) Setup the 'Update from Library' dialog as...
View ArticleRe: AATK_1719 released
pavan,Download the zip file and in there you will find a file called READ_ME_FIRST.txt. In this document you will find the instructions on how to get AATK setup on your machine. There is a lot of...
View ArticleRe: can`t close DxDesigner /viewdraw at the end of script !
If you could post the rest of your script, it would be helpful. It's likely that you have a hook into something that you do not dispose of properly. A view, doc, sheet, or something. Normally you...
View ArticleHow to verify sub-Contractor Land Patterns
Hello,I'll try to be brief. I am new to this Company Microwave Innovations, they brought me in to Lead and Start PCB Design inhouse.How ever, I used pads from its start till about 1996. I have come...
View ArticleRe: L-Edit in Ubuntu
Robert, Bad substitution sounds like there may be an issue with the shell you're using. Perhaps you should try a different one. You might also consider running a full installation of Windows with...
View ArticleRe: L-Edit in Ubuntu
Thank you Guy.I expect you are write that the problem is that it was written for /bin/sh and I was using /bin/bash. What I did find is that if I commented out any if statements that utilized "=="...
View ArticleRe: Electrical System Design and Harness Engineering Feedback
Pat -- I will follow up with you by email.
View ArticleRe: can`t close DxDesigner /viewdraw at the end of script !
HiPatrick,the scriptsnipped above is everything I got. Then idea was to write a script which will close the current running DxD and after copy the Project.But i never came further because I didn’t even...
View ArticleRe: How to set via space in differential pair routing
Let's asume that you want the distance between the two via's of a differential pair to be 0.5mm. - Create a Netclass "LVDS" for the LVDS signals and add the appropriate nets.- Create a clearance rule...
View ArticleRe: can`t close DxDesigner /viewdraw at the end of script !
Here's how I'd do it. I verified that it works without errors. Note I use vb.net. You may need to make minor adjustments if you use vbscript and/or EFM's. Public app as ViewDraw.Application...
View ArticleRe: Using VB script to export IDF and DXF formats from Expedition PCB
Hi, its me again. Thanks for all the support so far, now I have my Tool up and running, doing various exports for me.My problem is now the DXF-Engine / Exporter. I want to export all the Traces from...
View Articlechange of community "credentials" (username, reference email ...)
Dear Community / Community Admin, how do I change my username, or reference email ?Is there any way to do so ? I went through a few quick Start guides (*.docx) posted in this Forum, but nothing. Thanks...
View ArticleRe: Using VB script to export IDF and DXF formats from Expedition PCB
Hi, Using the layer number should work but it has to be passed as an integer type which might have been the issue if you used layername = i. Then it will be sent as a string type so the export engine...
View ArticleFlexnet TIMEOUT option support in PADS Logic.
The Flexnet License Administration guide indicates that the TIMEOUT option needs to be supported by the FLEX-enabled application. I can find no documentation on whether this is supported by PADS Logic....
View ArticleRe: How to verify sub-Contractor Land Patterns
If they have been building it, the parts probably match the datasheets. If every thing was done by outside contractors, of course there will be no libraries. Or consistency from board to board. My...
View Article