Quantcast
Browsing all 4541 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

Re: Cross-probing from Layout to Schematic stopped working

Hi DanMaybe you have accidently disabled 'Receive Selections' in the 'PADS Layout Link' dialog?regards Klaus

View Article


Re: Cross-probing from Layout to Schematic stopped working

Yes, that was exactly it! Thank you so much!

View Article


Image may be NSFW.
Clik here to view.

Re: Merge Profiles on Communities/Ideas

This has been asked on several occasions. And after some investigation, this may be possible, tho I need to test  this possibility.

View Article

Re: what is the different between PADS 9.4 vs PADS 9.5 ??

Hi Milostnik, Thanks for reply and sorry for delay from side.i have not access the support net,if you have any details please share to me

View Article

How to increase the working design are size

hi, can any one suggest a solution to increase the working design size. Thanks;Krish

View Article


Image may be NSFW.
Clik here to view.

Can you load older Pads-Layout & Pads-Logic designs into DX Designer?

I've haven't used Dx Designer before. Can you link/load older V9.5 files from Pads-Logic and Pads-Layout into Dx Designer to make changes? Fred

View Article

Visual IBIS Editor not editing

My Hyperlynx seat is fully functional, no problem, but when I open IBIS files in the editor I do not get to change them in the graphical editor.  The "editing" function is greyed out even though I have...

View Article

Re: How to increase the working design are size

It's already 56" x 56". How big do you need?

View Article


Re: Wire Style Set

VishalYou have selected "Composite Texts" category. Now select the green Add icon at the top left corner of the dialog box to Add a "Composite Text" field that you can build up with the pieces you...

View Article


Image may be NSFW.
Clik here to view.

Use of project properties to control Severity and Availability for a custom DRC

Our intention is to create project properties which will allow us to control Severity and Availability for a custom DRC. The DRC is made for Capital Integrator. There are different sets for DRC...

View Article

Re: Can you load older Pads-Layout & Pads-Logic designs into DX Designer?

To open PADS Logic designs you use File - Import - PADS or File Import - PADS Logic depending on which version of DxDesigner you are using. Before doing so you should do a little reading up to...

View Article

What is the max size of a document attachment?

What is the max size of a document attachment? can it be changed for a specific document to enable a 13MB file?

View Article

Image may be NSFW.
Clik here to view.

pads vx.2 customize visual style setup can't save.

Tools--Customize--Options Visual Style,Select Office Microsoft 2007 Aqua Blue Black Silver of these options, restart the software will automatically become Office Microsoft 2003!Is this bug? 

View Article


Re: What is the max size of a document attachment?

Hi Nick – 10 MB is the current limit. It can be increased, but wondering if for a one time exception we could explore another option. Let me reach out to you  thru email and we can  explore  if this is...

View Article

Re: DxDesigner Rename Net Names

I have a routine that does something similar.  I believe you are on the right track,  with your statement: netLabel.TextString = netArrayEntries.newNetName I don't remember the details of what went...

View Article


Image may be NSFW.
Clik here to view.

Re: pads vx.2 customize visual style setup can't save.

I noticed the same thing a couple of days ago.  Definitely a bug.  Seems like what is happening is that when it writes the VisualStyle registry key it isn't giving the full style name and since the...

View Article

Re: Visual IBIS Editor not editing

In the Visual IBIS Editor Pulldown menu item Edit > Preferences dialog there is a checkbox in the lower left corner called "Enable licensed features". If you check that checkbox then the editing...

View Article


Image may be NSFW.
Clik here to view.

Composite table, Wire table & Revision table not visible after applying style...

Hello,composite table, Wire table & Revision table is not appearing even after applying style set, please guide me as how can i make it visible, what is the matter why its not showing after...

View Article

Image may be NSFW.
Clik here to view.

Re: Error - Pin count in a cell is different than in the referencing part

I experienced exactly the same problem.The only solution I found is:- make copy of the footprint- remove/add pins- add new cell name to the PDBYou can also make copy of the symbol, add pins and then...

View Article

Re: Composite table, Wire table & Revision table not visible after applying...

Please do update border after defining the style set. Any new nodes in defined in design node at style set level will get reflected through update border action.

View Article
Browsing all 4541 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>