Quantcast
Channel: Mentor Graphics Communities: Message List
Browsing all 4541 articles
Browse latest View live

Re: 3D EM simulation of differential vias with ac coupling capacitors.

The 3d solver in HL9.2 would not take it into consideration. it was one of its limitations. A second step outside of the 3d solver was required in linesim to connect ports on the pads of the capacitor...

View Article


Image may be NSFW.
Clik here to view.

Re: How to controll the decimal (trailing)units in PADS ??

You can increase decimal places (i.e. significant digits) from the changing the Dimensions Toolbar -> Options -> Text -> Precision:Linear XX. The preview window will show you all your options...

View Article


Re: Custom Query to report wire Part # and MC # in a single column

Muhammad, I could not find a concatenate query which has 3 expressions. I would appreciate if you send me any documentation explaining the queries and expressions with some examples that comes out of...

View Article

Image may be NSFW.
Clik here to view.

Query to Replace Terminal Part# with Termianl BOM ID

I want to replace the Term PN with BOM_ID's due to our business process.I would like to know if a query can be written to pull the generated BOM_ID  for the Terminal in a separate custom column.Your...

View Article

Image may be NSFW.
Clik here to view.

Re: 3d VIA MODELLING USING HYPERLYNX V9.2

Thanks for the reply I simulated two cases in differential via with back drill and without back drill also taking ground vias into effect, below is the geometry that i took into consideration ground...

View Article


Image may be NSFW.
Clik here to view.

DECIMAL POINT IN DXDATABOOK VALUE FIELD

How can i display in dxdatabook a value like 8,192MHz instead of 8M192Hz? Here are my settings (VALUE field): Thanks

View Article

Image may be NSFW.
Clik here to view.

Problem with .drl after loading in gerbv

Hi,I have a problem after loading gerber files and drils file in gerbv. After changing file format to Trailing (zero_supression), inch (units) and 2 (digits) holes from drill file are shifted. Below is...

View Article

Re: Problem with .drl after loading in gerbv

Ok. I find the the reason. All gerber files are positioned "bottom left" with offset (1000,1000), but NCDrill nedd offset (1005,1005).

View Article


Image may be NSFW.
Clik here to view.

Re: Custom Query to report wire Part # and MC # in a single column

You can add more arguments to concatenate (and generally any applicable expression) by clicking the green arrow-head on the left as such:  ThanksMuhammad

View Article


Re: Custom Query to report wire Part # and MC # in a single column

Muhammad, It works perfectly fine.I appreciate you time and help,Thank you, Arjun

View Article

Re: Custom Query to report wire Part # and MC # in a single column

Great! Glad I could help. CheersMuhammad

View Article

Re: Custom Query to report wire Part # and MC # in a single column

Yes,  Also I realized I cannot have Part Number on my dwg.I changed Part# to Bom_ID attribute in the same query and it worked fine with this Wire table.Thank you,- Arjun

View Article

Image may be NSFW.
Clik here to view.

Re: Query to Replace Terminal Part# with Termianl BOM ID

Hi Arjun The issue with such a query is it would return two terminal BOM ID's, one at this connector and one at the other end. There is no way I know of in the query builder that would differentiate...

View Article


Re: embedded or Oracle database

I found this relevant:Embedded Database FAQ

View Article

Re: PARTQUEST no longer functional

Gary,      Tried reinstalling Partquest after complete uninstallation, still same issue. I am able to use direct download from PartQuest, save footprint in c:pq_unzip but not able to "Import PartQuest...

View Article


Re: PARTQUEST no longer functional

Gary,    Also worth mentioning, is that Partquest worked with VX1.1 prior to upgrading to VX1.2. Now neither version works with that add-on. My colleague also updated from Pads 9.5 directly to VX1.2...

View Article

Re: Symbol library import error

There could be something wrong with the syntax of the xml file.You should open an SR in SupportNet if you are still having the problem

View Article


Setting a PCB heat flux

Hi! I'm currently using FloTHERM XT as part of my master thesis in thermal simulation. I've successfully imported and set all powers individually on components after filtering the smaller ones out in...

View Article

Impedance discontinuity of differential vias.

Why extra stubs in differential vias have more capacitive discontinuity as compared to inductive discontinuity.Thanks 

View Article

Re: Query to Replace Terminal Part# with Termianl BOM ID

Muhammad, thank you for trying , I see what you mean.We tried out the query and are getting BOM_ID from both ends as well.Now planning to go with a custom based query.Best Regards,-Arjun

View Article
Browsing all 4541 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>