If I understand your setup correctly then what you are trying to achieve isn't possible in the Xpedition flow. Though you can add the Cell Name from xDX Databook, this still has to match the cell defined in the library for the part. The Central Library uses Part Number as the unique identifier for a part and associates this with a set of cells, default and optional alternates as defined in the part database (PDB); you cannot break this association and dynamically assign cells, the library is designed to ensure parts are correct by construction when created.
↧