Re: Variant Manager Automation Problem EEVX.1

$
0
0

Wolfgang,

In VX releases, you must specify the correct progid in the objects, IE:

 

From an opened application:

     Dim sComVersion : sComVersion = Scripting.GetEnvVariable("EXP_PROG_ID_VER") : If sComVersion = "" Then sComVersion = "1"

     Dim progID : progID = "MGCVARIANTGUI.MGCVariantGUICtrl." & sComVersion   

     Set addinObj = launchAddin(progID, addinName, associatedScript,addinPlacement, shortcutKey)

     Scripting.AddTypeLibrary("MGCVARIANTGUI.MGCVariantGUICtrl." + sComVersion)

 

This will get you access to the enums.

 

Regards,

Al